RHODUL OUTDOOR HOUSING INSTALLATION AND SERVICE GUIDE (8000-2830-05, REV. A)
4 of 14
CAUTIONS
You should have two boxes: one for the outdoor
housing, the other for the bubble assembly.
Protect the bubble assembly by leaving it in its
box until you are ready to install it.
Do not run data and power cables adjacent to
or in the same conduit as line voltage mains
power.
SensorNet 485 networks require 22 AWG
unshielded
cable. Do not exceed 32 devices
per cable run.
RS422 networks require 22 AWG shielded
cable. Do not exceed 10 devices per cable run.
Manchester networks require 18 AWG shielded
cable. Do not exceed 3 devices per cable run.
Always terminate the camera dome connected
at the end of a cable run.
The outdoor housing contains an environmental
PC board. Touch the metal housing to
discharge static electricity before
touching this
board. Also, use a jeweler’s 2.5mm (0.1")
slotted screwdriver to tighten PC board
connectors. Wider blade widths can damage
connectors. Do not over tighten connectors.
When connecting the housing and eyeball
assembly to the outdoor housing:
- Remove both
slot covers to keep the
camera from overheating
- Keep cables entering the housing away from
the heater assembly
- Check heater fan operation. Both fans must
be on to prevent overheating.