Sensormatic VM96 INS Manual del operador Pagina 47

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 122
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 46
Using the TOUCH TRACKER 3-17
Note
Outputs within a Sequence will always change to their “closed” state when
the Sequence is initiated. For example, if the output is a light (and the
light’s closed state is “on”), then the light will turn on when the Sequence is
initiated. If the output is a door lock, (and the lock’s closed state is
“unlocked”), then the door will unlock when the Sequence is initiated. If,
when the Sequence is initiated, the output is already in its closed state, it will
remain in that state even after its dwell time is up.
Both types of sequences will run repeatedly until you select the monitor
where the Sequence is running and either:
· Press the
Seq button (which stops the Sequence permanently),
· Issue a camera command, i.e., pan, tilt, zoom, focus, iris (which also
stops the Sequence permanently), or
· Press the
Hold button (which stops the Sequence temporarily).
1
1 2 3 4 5 6 7 8 9 77 Lobby
12 Front Door
1
Seq. Name
12:21:31 P Mon May 17 1999
W1-M2A
Facility Name
Figure 3-10: Sequence information.
When you initiate a Sequence,
the Sequence Name is displayed
here.
As each action within the
Sequence is called up, its
corresponding name and
number are displayed here.
Notice that when the action
changes, so do the name and
number.
As each action within the
Sequence is called up, the
corresponding camera name
and number for which the action
was defined are displayed here.
Notice the name and number
change whenever the action
calls up a new camera.
Vista de pagina 46