Alarms, Areas and Home Settings 4-11
6. Repeat steps 4 and 5 for each area you want to establish.
Note: You will see the following error message under certain conditions:
Error programming areas
Focus Far to continue.
• If you attempt to program a boundary that passes the starting point of the first area
• If you move the camera left after establishing the first boundary
Return to step 1 and start again.
7. When the last area boundary is set, press Focus Far.
The following confirmation message appears:
Areas saved successfully
Focus Far to continue.
Press Focus Far to continue.
8. When the Alarms/Areas/Home screen appears, do one of the following:
• If you want to configure the alarm actions, continue with Configuring Alarm
Actions on page 4-2.
• If you want to configure the input states, continue with Configuring Normal
Input States on page 4-5.
• If you want to set the “home” position, continue with Assigning the Dome’s
Home Position on page 4-7.
• If you are finished making changes, press and hold Iris Close, then press Focus
Near or Focus Far to save your changes and exit the utility.
5
• If you want to make changes to other settings, use the Tilt control to move the
highlight bar to Exit, then press Focus Far. The Dome Configuration Menu
appears. Continue with What To Do Next found on page 4-13.
Programming Presets
A preset is a programmed video scene with automatic pan, tilt, zoom, focus and iris settings.
Presets may be assigned to alarm actions or as the “home” position for the dome. Up to 96
presets whose positions are saved in the domes firmware may be programmed. Domes
installed in SensorNet or RS-422 networks support up to 96 presets. Domes installed in
Manchester networks support up to 64 presets. If you attempt to program a preset numbered
higher than 64 in a Manchester network, the controller beeps.
VM96 and AD matrices installed as RS-422 and SensorNet networks support “virtual” views.
This means that the pan, tilt, zoom, focus, and iris settings are stored within the controller,
not the dome. You cannot use the views that you define on those systems as the home
position or an alarm action. You must use the presets programmed using this utility.
5
This command is not supported with Manchester.